Search results - "cut"
DSC02143.JPG
No security here...1372 viewsMDU wiring. Workmanship issues here as well as secutity and NEC. Lockbox lid is missing. Wiring is hanging out. Not grounded and too close to power.
DSC02109.JPG
It's a metal box, part of the power, Right???1287 viewsGrounded to an air conditioning cutoff switch. Ground wire not run properly or secured. Splitter not properly secured. Note the terminator on the input to the splitter. Another disconnect at the side of the house. Security issue.
DSC01319.JPG
Just let it all hang down1069 viewsOld cable plant cut and dropped into the tree limbs as part of a rebuild. Contractor failed to wreckout the old plant creating a safety hazard.
grdDSC00625.jpg
Ground to Air Conditioner Cutoff switch592 viewsHere's a grounding bar installed on the remote cutoff switch for an exterior air conditioner unit. The NEC permits grounding ONLY to the meter panel itself, not a remote switch or metal enclosure.
DSC01624.JPG
A true midspan drop connection1298 viewsCable strand was cut and removed as part of a street relignment and drops were left attached to an unsupported portion of strand.
20030910DSC01619.jpg
CATV 'grounded' to air conditioning cutoff switch466 views'Grounded' to an unapproved grounding point. A remote A/C cutoff switch is not part of the primary grounding electrode network.